The Rankine cycle
The Rankine cycle is the basis of steam power plants, both fossil and nuclear. Water is compressed by a pump (3→4), heated, evaporated and superheated in the boiler at constant pressure (4→1), the steam expands in the turbine (1→2) and condenses in the condenser at constant pressure and temperature (2→3). Heat is added in the boiler and rejected in the condenser.
Main formulas
- Turbine work: l_T = h₁ − h₂, the real h₂ = h₁ − η_oi·(h₁ − h₂s), where h₂s is after isentropic expansion to p₂.
- Pump work: l_p ≈ v₃·(p₁ − p₂)/η_p (small, about 1 % of l_T).
- Heat added q₁ = h₁ − h₄, heat rejected q₂ = h₂ − h₃.
- Thermal efficiency η_t = (l_T − l_p)/q₁ = 1 − q₂/q₁.
- Steam rate d = 3600/(l_T − l_p), kg/(kW·h).
Superheat and reheat
Raising the live steam temperature and pressure increases the mean temperature of heat addition and the efficiency, but makes the exhaust steam wetter: above 12–15 % wetness droplets destroy the blades. So after the high-pressure part the steam is returned to the boiler (reheat at pressure p_r), heated to t_r and then expanded to the condenser. This raises the exhaust dryness and slightly raises the efficiency; the optimum reheat pressure is about 20–25 % of p₁.
The upper bound
The efficiency of the cycle does not exceed the Carnot efficiency between the highest and the lowest temperatures, and for an ideal cycle without losses it equals 1 − T_min/T_m, where T_m = q₁/Δs is the mean temperature of heat addition. The calculator shows both values.
Steam properties
The calculation relies on the IAPWS-IF97 formulation (regions 1–5): the properties of the points come straight from the basic equations, without tables or charts. The same functions run on the Steam page.